ADD SUFFIX BP1
|
"Break Glass-Push
Button" model, momentary operator behind glass
|
ADD SUFFIX BP2
|
"Break Glass-Push
Button" model, maintained (push on/push off) operator behind glass
|
ADD SUFFIX TG
|
Two position toggle
switch model, maintained toggle behind glass:"Break Glass -Operate
Switch"
|
ADD SUFFIX P1
|
Two position selector
switch model, maintained both positions (standard): "Break Glass-Operate
Switch" (Note 2)
|
ADD SUFFIX P3
|
Tree position selector
switch, maintained all positions (standard):"Break Glass-Operate
Switch"(Note 2)
|
ADD SUFFIX K1
|
Two position keyed
selector switch model, maintained both positions (standard):"Break Glass-Switch"
(Note 2)
|
ADD SUFFIX K4
|
Tree position keyed
selector switch model, maintained all positions (standard):"Break Glass-Switch"
(Note 2)
|
ADD SUFFIX IL
|
Iluminated operator
model with 24-120V AC/DC red LED (standard-specify other voltage ) (Note1)
|
ADD SUFFIX XD
|
Extra depth model for twelve contact block capacity
|
ADD SUFFIX SL
|
Specific legend ( specify when ordering )
|
NOTE:
|
Contact blocks supplied
separately: specify accesories PILNOCB and/or PILNCCB. See Series PIL
Accessories below.For electrical ratings, see CONTACT BLOCK CHARACTERISTICS
at Note 3 page 18. NOTE THAT CONTACT BLOCK CAPACITIES SHOWN ABOVE ARE
50% GREATER THAN OLD CAPACITIES INDICATED IN BULLETIN 120.2.
|
*NOTE
1: |
For optional incandescant or neon lamp: Add addendum IC or NE to suffix IL (120V
standard-specify other). Suffix IL illumination option available on standard
and suffix BP1/P1/P3 models but not available on suffix BP2/TG/K1/K4 models. |
*NOTE 2: |
For
operation other than (standard) maintained in all positions on suffix P1/P3/K1/K3
models, specify when ordering. See Series PIL Accessories (below) for descriptions
of two/three position selector and two/three position keyed selector switches
available. Keyed selector switches include two keys. |
-
Operator automatically
releases when glass is broken (standard-Suffix BP1 / BP2 models require
button to be manually depressed)
-
Optional suffix TG
/ P3 / P3 / K1/K4 models are labeled: "Break Glass-Operate Switch"
-
Contact blocks rated
10 AMP continuous up to 600 Volts*
-
Accepts up to four
contact blocks in 3.5 inch depth backbox
-
Extra depth model
accepts up to eight contacts blocks: Add model suffix XD
-
Compact 4.5 x 4.5
inch metal backbox has red enamel finish with 1/2-3/4" inch knockout provided
bothom and back
-
Standard models: Type
PILNCCB / PILNOCB contacts remain open/closed with glass intact--close/open
when glass is broken
-
Suffix BP1/BP2/TG/P1/P3/K1/K4
models: Type PILNCCB / PILNOCB contacts remain closed/open with glass intact--open/close
when glass is broken and device manually actuted
-
Illuminated model
includes 120V lamp standard (specify other voltage): Add model suffix IL
-
Double strength glass standard - single strength glass available upon request (surcharge applies)
-
One double strength
replacement glass included with each ST120
-
SPECIFIC LEGENDS AVAILABLE
IN ANY LANGUAGE: Add model suffix SL (specify text)
-
*NOTE: Contact block (s) supplied separately.
See Series PIL accessories